Contact Resistance: The Number That Decides Whether Your Slip Ring Works

November 14, 2026 2 min read
Contact resistance measurement on a slip ring

Every slip ring is tested for insulation resistance before shipment, and almost every one passes. The test that separates a good unit from a marginal one is contact resistance, measured circuit by circuit with a four-wire method.

Why four wires

A two-wire ohmmeter measures the contact plus the lead resistance plus the probe contact. At 10 mΩ the lead resistance is comparable to the value being measured, so the reading is meaningless. A four-wire Kelvin measurement drives current through one pair and senses voltage across another, isolating the contact itself.

What the numbers mean

  • Signal circuits with gold contacts: 5–20 mΩ per circuit is normal for a new unit.
  • Power circuits with silver-graphite brushes: 1–5 mΩ, lower because the contact area is larger.
  • A reading above 50 mΩ on a signal circuit indicates a plating defect, contamination or insufficient brush force.

Change over life

Contact resistance rises slowly as the contact surface oxidises and brush material transfers. A rise of 30% over several million revolutions is expected. A doubling within a few thousand revolutions indicates a design or assembly problem, not normal wear.

What to ask for in the report

Ask for the measured value per circuit, not a single pass/fail line. On a 231-circuit assembly the average can hide a single bad channel, and that channel is the one that will produce a field fault.

We record every circuit on every unit. If you need the raw data as a CSV alongside the PDF report, say so in the enquiry and it will be included.