Skip to content
● Engineering response within 24 h admin@ingiant.com ISO 9001 · CE · RoHS
Ingiant Technology

Quality & Certifications

Every unit is electrically tested — contact resistance, insulation, dielectric strength and rotation noise — with a serial-numbered report inside the box.

Quality laboratory and electrical test bench

Slip rings fail in service for four reasons: contact wear, insulation breakdown, seal ingress and mechanical run-out. Each of these has a test, and each test is performed on every unit we release — not on a sample from the batch.

Incoming and in-process control

  • Contact material certification per lot: gold alloy, silver graphite and gold-plated beryllium copper are verified for composition and hardness.
  • Machined housing dimensions checked against the drawing with CMM sampling; bore concentricity and face run-out recorded.
  • Brush force measured on a gram gauge for every brush block assembly.
  • Insulation resistance checked at 500 V DC after winding and again after housing.

Final electrical test, 100% of units

  • Contact resistance: four-wire measurement, recorded per circuit in the report.
  • Insulation resistance: minimum 1,000 MΩ at 500 V DC for standard builds.
  • Dielectric strength: 500 V AC for signal circuits, 1,000 V AC for power circuits, 1 minute, no breakdown.
  • Dynamic noise: rotation at rated speed with an oscilloscope trace to catch intermittent contact.
  • Rotation torque and starting torque recorded against the specification.

Environmental qualification

IP65 and IP68 housings are qualified with dust and water ingress testing, plus thermal cycling between the declared temperature limits. Offshore and subsea assemblies are pressure-tested to 1.5× the declared working depth. Vibration and shock profiles are run where the customer’s application calls for them.

Life and first article

Rotation life is bench-tested to the customer’s declared cycle count before shipment release; wear rate is documented so replacement intervals can be planned. First-article inspection reports follow the PPAP structure for automotive and medical customers, with dimensional, material and functional sections.

Certifications and documentation

  • ISO 9001:2015 quality management system.
  • CE marking for applicable machinery assemblies, RoHS and REACH declarations on request.
  • Export documentation: commercial invoice, packing list, certificate of origin, and test report per serial number.

Send us your drawing. We send back a design.

Circuits, current, bore size, IP rating, temperature — give us the parameters and our engineers return a feasibility note, drawing and quotation within 24 working hours.