CAP020-12-1A Capsule Slip Ring, 20 mm Diameter
A 20 mm capsule with twelve circuits, priced for volume instrument programmes and available…
CAP012-6-2A | dimensions in mm unless noted
A 12 mm diameter capsule with six circuits at 2 A for dental lamps, endoscopes, camera gimbals and instruments where every cubic millimetre is budgeted.
Lead time: 15–25 working days for standard variants · prototypes from 10 working days. MOQ from 1 pc for evaluation.
The CAP012-6-2A is our smallest production capsule: 12 mm outside diameter, 30 mm long, six circuits at 2 A. It is used where a designer has already given up millimetres elsewhere and needs the rotating connection to disappear into the assembly.
At this size the brush geometry and ring plating decide the life. Contacts are gold-plated and the brush force is set per circuit rather than by a single spring, so low-level signals do not open up when the assembly is mounted at an angle or vibrated.
Six circuits is enough for a two-axis joystick, a camera video pair with power, or a dental lamp with intensity control. Where more circuits are required in the same diameter, the CAP020 family is the next step.
| Outer diameter | 12 mm |
|---|---|
| Length | 30 mm |
| Circuits | 6 |
| Current per circuit | 2 A |
| Voltage | 240 V AC / 300 V DC |
| Rotation speed | 2,000 rpm max |
| Contact resistance | ≤ 20 mΩ |
| Insulation resistance | ≥ 500 MΩ |
| Temperature range | -20 to +80 °C |
| Contact material | Gold-plated copper alloy |
| Termination | Flying leads 150 mm |
| Mounting | Shaft mount, collar clamp |
Values above are typical for the standard build. Tighter tolerances, alternative materials and extended temperature ranges are available on request.
Send a 2D envelope drawing or a reference photo — we work from both. NDAs are signed before confidential drawings are exchanged.
Discuss a custom variant
A 20 mm capsule with twelve circuits, priced for volume instrument programmes and available…
Send the duty cycle, envelope limits and interface types. You will get a data sheet marked up against your requirements, not a catalogue page.
Circuits, current, bore size, IP rating, temperature — give us the parameters and our engineers return a feasibility note, drawing and quotation within 24 working hours.