Packaging is the highest-volume slip ring application we serve, and the least glamorous. Rotary fillers and cappers turn continuously at speed, sit in washdown environments and are maintained on a fixed schedule whether or not the ring needs it.
Sealing under washdown
Detergent sprays and pressure rinses defeat IP54 designs quickly. The IP65 variants in the DHT and DHS families use dual lip seals and a sealed cable entry, which is what allows a 12-month maintenance interval instead of three.
Speed versus life
At 2,000–3,000 rpm, brush wear is a function of contact force and surface speed. For high-speed heads we reduce brush force and increase contact area, accepting a slightly higher contact resistance in exchange for longer life. The application decides which trade is correct.
Typical build
A filler head usually needs 12–24 circuits: motor power, valve control, sensor inputs and a communication pair. The DHT060-24-5A with an IP65 option is the standard fit, combined with an RU-4-10 rotary union for the air circuits on the same shaft.